Description
TV15 Tempering Valve 1/2 Male
Product Specifications:
- Cold Water Supply Temperature: 5˚C – 30˚C
- Hot Water Supply Temperature: 60˚C – 90˚C
- Set Temperature: 50˚C standard (must be commissioned onsite by installer)
- Accuracy of Outlet Temperature: +/- 3˚C (as per AS4032.2)
- Maximum Working Pressure (Static): 1400Kpa
- Maximum Working Pressure (Dynamic): 500Kpa
- Minimum Flow Rate: 3.6L/min under outlet pressure 10Kpa